Appendix C: BMC Sensor Tables Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.1
Intel order number G26942-003
174
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Readi
ng Type
Event Offset Triggers Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Of
fsets
Event
Data
Rearm
Stand-
by
Button Sensor
(Button)
09h All
Button/Switch
14h
Sensor
Specific
6Fh
00 – Power Button
02 – Reset Button
OK AS _ Trig Offset A X
BMC Watchdog 0Ah All
Mgmt System
Health
28h
Digital
Discrete
03h
01 – State Asserted Degraded As Trig Offset A -
Voltage Regulator Watchdog
(VR Watchdog)
0Bh All
Voltage
02h
Digital
Discrete
03h
01 – State Asserted Fatal
As
and
De
– Trig Offset M X
Fan Redundancy
1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As
and
De
– Trig Offset A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 – Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperature
01h
Digital
Discrete
03h
01 – State Asserted Fatal
As
and
De
– Trig Offset M X