Chapter 4: Programming
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 113
Remote access
The panel programming can be accessed remotely via configuration software.
A remote access can be gained via IP, GPRS, PSTN or ISDN connection,
depending on the available panel hardware configuration and settings.
Note: Connection via USB cable is not a remote connection.
By default, the menu is accessible remotely with the same installer PIN. The
remote access PIN can be altered using menu ā3.1.n.2.2 Remote PINā on page
163.
The supervisor have an access to his Remote PIN only if the option ā8.7.8.2
Remote PINā on page 253 allows it.
Cautions
⢠Once enabled, remote PIN can be neither disabled nor changed locally, and
the Remote PIN menu is disabled.
⢠If PIN length gets changed (via ā8.7.4 PIN lengthā described on page 250)
while remote PIN is enabled, the configuration software will not be able to
connect the programmed panel anymore. It will be necessary to delete the
panel configuration in the software, and then recreate it.
The remote configuration is allowed only if the option ā8.7.8.1 Remote configā on
page 253 is set to Yes.