EasyManuals Logo
Home>Interlogix>Security System>ATS3500A-IP-MM

Interlogix ATS3500A-IP-MM Installation And Programming Manual

Interlogix ATS3500A-IP-MM
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Chapter 3: System functions
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 53
Inhibit and isolate
A faulty device can be inhibited or isolated.
Inhibit
A zone is inhibited from indicating normal or active status. It becomes excluded
from functioning as part of the system for particular time. However, tampers are
still monitored.
The zone is inhibited until the next unset.
A zone can be inhibited automatically when using the forced set functionality. It is
configured via menu “8.4.4 Forced seton page 244 in Chapter 5 “Menu
reference”.
Isolate
A zone or a bus device is inhibited from indicating normal or active status. It is
excluded from functioning as part of the system permanently, until de-isolating by
the manager or installer.
Zone shunt
A shunt procedure inhibits zones, when active, from generating an alarm during a
certain time period.
A zone can be shunted in the following ways:
Manually by the installer. Use menu “1.2.1.9 Shunt zoneson page 124.
By a schedule. See “Calendaron page 77 for details.
By a conditional filter. See “Condition filterson page 74 for details.
By a zone with Shunt type. See “Zone typeson page 45 for details.
Caution: There is a limitation of the number of zones that can be shunted
simultaneously. The limit is set in “4.2.n.7.3 Shunt limiton page 190.
During the shunt time the zone is inhibited.
If the zone is still active after the shunt time has expired, the zone will generate
an alarm, depending on the zone type and the status of the area.
For particular users (depending on their user options) the shunt is active during
an extended shunt time.
Before the shunt timer expires, a warning may be given.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals