Chapter 8: Regulations
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 307
Reporting devices
Panel can support 1 GSM device connected onto MI bus.
• ATS7310: GSM communication device
• ATS7440: IP/GPRS alarm dialer
• ATS7700: PSTN interfance board
When any option, any additional function or any additional zone type in this
section does not comply with the EN 50131 requirements, the EN 50131 Grade 3
label must be removed from the system. See also “EN 50131 compliance
precautions” below.
EN 50131 compliance precautions
Installation
In order to install an EN 50131 compliant system, please make sure that all
system components are EN 50131 compliant. See “EN 50131 Grade 3 certified
components” on page 306 for more details.
Programming
Make sure that all system settings are in line with regulatory compliance
guidelines. See “EN 50131 Grade 3” on page 303 for more details.
Size of log / event history
For full EN 50131 Grade 3 compliance, the system must store at least
500 events.
Marking
It is only allowed to mark the system with the EN 50131 Grade 3 label, if the
following requirements are met:
• All system components are EN 50131 compliant. Refer to “EN 50131 Grade 3
certified components” on page 306.
• All settings are done according to “EN 50131 Grade 3” on page 303.
If any of these two items is not valid, the EN 50131 Grade 3 label must be
removed from the system.