Chapter 8: Regulations
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 303
Refer to appropriate sections and manuals.
Caution: When any option, any additional function or any additional zone type in
this section does not comply with the EN 50131 requirements, the EN 50131
Grade 2 label must be removed from the system.
Additional functions
The Wireless PIR Camera functionality brings along video verification feature,
this additional function is fully available without compromise to standards the
system complies to.
The Wireless PIR camera system consists of the following:
Advisor Advanced series control panel
ATS1238 Advanced Wireless DGP
TX-2344-03-1 Wireless PIR Camera
ATS7310 GSM/GPRS Module
These PIR camera settings have no influence on EN 50131 compliance:
2.2.2.n.4.9.1.1.2 Frame rate for all event types
2.2.2.n.4.9.1.1.3 Pic resolution for all event types
2.2.2.n.4.9.3 Pic auto deletion
4.5 Cameras
9.1.n.4.5 Vid dest port
9.3.n.10 Max Pics 24h, 9.3.n.7.9 Max Pics 24h
EN 50131 Grade 3
Required settings
The following options and values are mandatory for EN 50131-1 Grade 3
regulations:
All Grade 2 required settings (see “EN 50131 Grade 2on page 302).
PIN length should be 6 digits minimum. See also “8.7.4 PIN length”.
3.2.n.6 User group options, set (6) Isolate, (22) SMS reporting, (23) SMS
control to No for all user groups except Installer.
4.1.n.6.7 Anti mask, set to Yes for all I&HAS movement detectors
8.1.3.1 Armed display, set to 00’00
8.3.5 View EE timer, set to Off
8.4.1 RTS options, set Zone masking condition to Yes
8.4.2 Inhibit includes, set Zone masking condition to Access Level 2
Battery test should be performed daily. See “1.2.9 Battery teston page 135
for details.
The following features are not allowed (not evaluated):
Keyswitch zone types to set and unset the system. See “Zone typeson page
45.
Presetting indication and any automatic override of set prevention.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals