Goodrive350-19 series VFD Commissioning
- 56 -
If PLC control is used, speed signal and other input and output signal functions need to be
adjusted according to the actual control logic.
This macro can meet the requirements of most lifting application cases, and the performance
parameters have been optimized and do not need to be adjusted in most cases. If an exception
occurs, see the function parameter chapter for adjustment or contact the technical support.
5.7 Commissioning winching in closed-loop vector control (applicable to
lifting in mineral wells and winches)
5.7.1 Wiring
(+) PB
GD350-19 VFD
R
S
T
R
S
T
U
V
W
PG
PE
S1
S2
S3
S4
COM
Brake output
VFD fault
output
RO1A
RO1B
RO1C
RO2A
RO2B
RO2C
Lifting
Lowering
Fault reset
Upward position limit
Braking resistor
COM
+24V
HDIB
HDIA
M
3~
GND
AI1
+10V
PW
+24V
Figure 5.7 Wiring for winching in closed-loop vector control (recommended analog reference 0V10V)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive350-19 Series and is the answer not in the manual?

INVT Goodrive350-19 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive350-19 Series
CategoryDC Drives
LanguageEnglish

Related product manuals