SV-DA200 series AC servo drives Appendix
‐271‐
10.3 General monitoring parameters
Setting value of
P0.15
Meaning Sign Unit
Corresponding
parameter
[0]
Motor rotation speed
r/min R0.00
1
Speed command
r/min R0.01
2
Pulse feedback accumulation
reference unit R0.02
3
Pulse command accumulation
reference unit R0.03
4
Retention pulse
reference unit R0.04
5
Hybrid control deviation
reference unit R0.05
6
Current torque
% R0.06
7
Main circuit DC voltage
V R0.07
8
Voltage of control power
V R0.08
9
Output voltage
Vrms R0.09
10
Output current
Arms R0.10
11
Drive temperature
℃ R0.11
12
Torque limit
% R0.12
13
Encoder feedback value
pulse R0.13
14
Rotor position relative to Z pulse
pulse R0.14
15
Load inertia ratio
% R0.15
16
Output power
% R0.16
17
Motor load rate
% R0.17
18
Molecule of actual electronic gear
- R0.18
19
Denominator of actual electronic
gear
- R0.19
20
Pulse speed command
r/min R0.20
21
Instant speed
r/min R0.21
22
PTP state
- R0.22