SV-DA200 series AC servo drives Running and operation
‐80‐
5.2.6 Alarm display
When the servo drive runs abnormally, it will perform fault alarm and stop automatically. At this time
the panel will display the fault alarm warning sign. The format is ErXX-X, of which, XX is the master
code and X is the sub code.
Please refer to appendix 10.4 for the meanings of the alarm or warning identifiers.
5.2.7 Alarm clearing
For those faults that can be cleared online, if the fault condition is removed, fault alarm display can be
cleared by short connecting the digital input terminal configured as fault clearing function
(P3.00~P3.09 configured as 0x004 or 0x104) with COM-. If the servo still has enabling command
input, the drive will not be able to clear the fault automatically.
For the fault alarms which cannot be cleared online, it can be cleared after repower on.