76
SECTION 3 - INDUSTRIAL APPLICATION
VECTOR 8 ENGINES
Base - April 2006 Print P2D32V001E
Symptom
Visible
trouble
Possible cause Repair Notes
Attributable to electrical malfunctioning.
Engine does not
accelerate
PWM signal not plausible or malfunction of
the accelerator potentiometer.
Check active diagnosis and any cabling
control. Replace, if required
The rail pressure does not correspond to
the one wanted
Check active diagnosis and any adjustable
flow control valve replacement.
If replacement does not resolve the trouble,
with a multimeter check that cabling works
properly
Power reduction
Rail pressure sensor does not work
properly
Check active diagnosis and any sensor
replacement
If replacement does not resolve the trouble,
with a multimeter check that cabling works
properly
Abnormal
performance
The pressure regulator does not work
properly
Check active diagnosis, check that the
connector is properly connected to the
pressure regulator and any sensor
replacement
If replacement does not resolve the trouble,
with a multimeter check that cabling works
properly
The engine
suddenly stops
(without previous
The fuel filter is clogged
Check diagnosis and then fuel filter
replacement
Check why clogging occurs
hesitations) and
does not restart
Rupture or malfunction of the rail pressure
sensor or of the o
erpressure
al
e
Check active diagnosis and any sensor
replacement
If replacement does not resolve the trouble,
with a multimeter check that cabling works
properly
Check and/or replace the overpressure valve
Coolant high
temperature
detected by the
engine sensor
None
Insufficient engine water level Request tank l evel reset