Maintenance
Daily or monthly maintenance activities
Fig. 47: Visual inspection of engine (4)
15
Exhaust line 16 Oil return (Turbocharger — Crankcase)
5.7.2 Inspecting engine running at idle speed — SL0-007
Previous tasks
Make sure that the following preconditions are met:
q Engine is running at idle speed.
q Engine is secured in the idle speed operating mode.
Specific safety instructions
Not applicable.
Consumables and equipment
Not applicable.
Inspection
u Observe the engine running at idle speed.
u Record and report any defect found on the engine (for example: leak, unusual noise, unusual
vibration, unusual exhaust gas color).
u Record and report any anomaly found on generator set display (for example: faulty param‐
eter).
u Make sure that authorized service personnel correct the defect.
5.7.3 Testing engine in operation (ESP application only) — SL008
Previous tasks
Make sure that the following preconditions are met:
q Operating test is planned and agreed with the responsible person for the electrical network.
q Electrical load is available for the test.
q Generator set is ready for operation.
104
© 2022 by Kohler Co. All rights reserved.
KD62V12 33521030301_8_1 EN_US 2022-09

Table of Contents

Other manuals for Kohler KD62V12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD62V12 and is the answer not in the manual?

Kohler KD62V12 Specifications

General IconGeneral
BrandKohler
ModelKD62V12
CategoryEngine
LanguageEnglish

Related product manuals