EasyManuals Logo
Home>Kohler>Engine>KD62V12

Kohler KD62V12 Operation And Maintenance Manual

Kohler KD62V12
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #112 background imageLoading...
Page #112 background image
Maintenance
Lubricating system
5.9.2 Checking prelubricating pump (optional) — SL103
Fig. 55: Prelubricating pump
u Check for abnormal noise when operating.
u Check pump for leaks.
u
Control pump functions.
u Identify and report any failure. Make sure that authorized service personnel correct the
defect.
5.9.3 Checking the engine oil level — SL001
q Engine stopped since at least 30 minutes.
q Preparatory maintenance activities are fulfilled. (For more information see: 5.5 Preparatory
maintenance activities, page 98.) .
112
© 2022 by Kohler Co. All rights reserved.
KD62V12 33521030301_8_1 EN_US 2022-09