Maintenance
Lubricating system
Fig. 57: Spin-on oil filters
1
Spin-on oil filter 3 Seal
2 Filter head
Spin-on oil filter removal
u Clean sealing area.
u Open spin-on oil filter 1 with filter wrench.
u Remove filter.
u Repeat procedure for all filters.
Spin-on oil filter installation
u Clean sealing area.
u Lubricate filter seal 3 with engine oil.
u Screw spin-on oil filter 1 in filter head 2 until it contacts base.
u Tighten filter by hand by 1/2 turn.
u Operate prelubricating pump to vent the filters.
u In the absence of prelubricating pump, disconnect TDC sensor (flywheel) and start engine
until oil pressure shows up.
u Reconnect TDC sensor.
u Check for leaks and damage.
u Retighten if necessary.
5.9.5 Replacing centrifuge paper filter — SL102
q Preparatory maintenance activities are fulfilled. (For more information see: 5.5 Preparatory
maintenance activities, page 98.)
q Original KOHLER oil filters with the seals are available.
q A suitable drainage container is available.
q The required quantity of approved oil is available. (For more information see: 5.14 Lubricants
and operating fluids, page 141.)
114
© 2022 by Kohler Co. All rights reserved.
KD62V12 33521030301_8_1 EN_US 2022-09