MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR
513
4.14.2 TRAVEL GEARS, MOTOR ADAPTER HOUSINGS AND FINAL DRIVES
CHANGE OIL
Legend for illustration Z25244
- A - View of the RH Final drive. The configuration of the
LH Final drive is the same.
(1) Travel gear
(2) Oil level gauge
(3) Oil filler plug
(4) Oil drain plug
(5) Connector for breather filter line. The breather filter
is located inside the center frame, see illustration
Z25243 on page 369.
(6)
Travel brake housing
R
EMARK
The travel gear brakes are dry type multiple disk
brakes. DO NOT fill the housings with oil.
(7) Motor adapter housing
(8) Oil level plug
(9) Connector for breather filter line, the breather filter is
located inside the center frame, see illustration
Z25243 on page 369. The port of connector (9) is
also used as oil filler opening.
(10) Oil drain plug
(11) Hydraulic motors
(12) Final drive housing contains the lubricating oil
for sprocket bearing lubrication.
(13) Oil level gauge
(14) Oil filler plug
(15) Oil drain plug
(16) Connector for breather filter line, the breather filter is
located inside the center frame, see illustration
Z25243 on page 369.