MAINTENANCE EVERY 500 OPERATING HOURS
7-59
HEATER/AIR CONDITIONING: CLEANING THE CONDENSER
Do not wash the condenser with a steam cleaner. Other-
wise, the condenser will get hot and may break down.
If there is mud or dust sticking to the air conditioner condenser,
cleanitwithwater.
If the water pressure is too high, the fins may get deformed.
When washing with a high pressure washing device, apply the
water from a reasonable distance.
CLEANING
1. Unscrew the steps on the right side (2 screws).
2. Swing out the steps together with condenser as far as it will
go.
3. Clean the condenser with water.
4. Screw the steps and condenser back into place (2 screws).