Long-life coolant (hereafter LLC) comes in several
types. Use ethylene glycol (EG) type for this
engine.
Before using LLC-mixed cooling water, fill the
radiator with fresh water and empty it again.
Repeat this procedure 2 times or 3 times to clean
up the inside.
Mixing the LLC
Premix 50% LLC with 50% clean soft water.
When mixing, stir it up well, and then fill into the
radiator.
Adding the LLC
Add only water if the mixture reduces in amount
by evaporation.
If there is a mixture leak, add the LLC of
the same manufacturer and type in the same
mixture percentage.
Never add any long-life coolant from a
different manufacturer. Different brands may
have different additive components, and the
engine may fail to perform as specified.
When the LLC is mixed, do not use any radiator
cleaning agent. The LLC contains an anti-corrosive
agent. If mixed with the cleaning agent, sludge may
build up, adversely affecting the engine parts.
KUBOTA's genuine long-life coolant has a service
life of 2 years. Be sure to change the coolant as
follows.
Changing the coolant
every 2000 hours or every 2 years
whichever comes faster
The procedure for the mixing of water and the
antifreeze differs according to the make of the
antifreeze and the ambient temperature. Refer to
SAE J1034 standard, more specifically also to SAE
J814c.
Antifreeze
Freezing point Boiling Point
*1
50Vol% -37 108
*1 At 1.013 x 10
5
Pa (760 mmHg) atmospheric pressure. A higher
boiling point is obtained by using a radiator pressure cap which
permits the development of pressure within the cooling system.
SERVICE EVERY 3000 HOURS
1. Checking the injection pump
Consult your local KUBOTA Dealer for checking the
injection pump.
SERVICE EVERY 1 YEAR
1. Checking the intake air line
WARNING
To avoid serious injury or death:
Stop the engine and remove the key before
checking the intake air line.
1. Check to see that the hose and the hose clamps
are tight and not damaged.
2. If the hose and the clamps are found worn or
damaged, replace or repair them at once.
BX231D
BX261D
(1) Hose
(2) Hose clamps
2. Checking the radiator hoses and
the hose clamps
WARNING
To avoid serious injury or death:
Be sure to stop the engine and remove the key
before checking the radiator hose and the hose
clamps.
1. If the hose clamps are loose or water leaks, tighten
them securely.
 PERIODIC SERVICE SERVICE EVERY 3000 HOURS
104
BX231D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota BX261D and is the answer not in the manual?

Kubota BX261D Specifications

General IconGeneral
BrandKubota
ModelBX261D
CategoryTractor
LanguageEnglish

Related product manuals