STV32 · STV36 · STV40, WSM ELECTRICAL SYSTEM
9-S37
[3] SERVICING
(1) Starter
Overrunning Clutch
1. Inspect the pinion for wear or damage.
2. If there is any defect, replace the overrunning clutch assembly.
3. Check that the pinion turns freely and smoothly in the
overrunning direction and does not slip in the cranking
direction.
4. If the pinion slips or does not rotate in the both directions,
replace the overrunning clutch assembly.
Commutator and Mica
1. Check the contact face of the commutator for wear, and grind
the commutator with emery paper if it is slightly worn.
2. Measure the commutator O.D. with an outside micrometer at
several points.
3. If the minimum O.D. is less than the allowable limit, replace the
armature.
4. If the difference of the O.D.'s exceeds the allowable limit,
correct the commutator on a lathe to the factory specification.
5. Measure the mica undercut.
6. If the undercut is less than the allowable limit, correct it with a
saw blade and chamfer the segment edges.
0000001168E
Commutator O.D.
Factory spec.
30.0 mm
1.181 in.
Allowable limit
29.0 mm
1.142 in.
Difference of O.D.'s
Factory spec.
Less than 0.02 mm
0.0008 in.
Allowable limit
0.05 mm
0.0020 in.
Mica undercut
Factory spec.
0.50 to 0.80 mm
0.0197 to 0.0315 in.
Allowable limit
0.20 mm
0.0079 in.
(1) Segment (a) Correct
(2) Undercut (b) incorrect
(3) Mica
0000001169E
KiSC issued 04, 2006 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota WSM STV32 and is the answer not in the manual?

Kubota WSM STV32 Specifications

General IconGeneral
BrandKubota
ModelWSM STV32
CategoryTractor
LanguageEnglish

Related product manuals