Ribbon cable connectors
• “Zero Insertion Force (ZIF) connectors” on page 201
• “Horizontal top contact connector” on page 202
• “Horizontal bottom contact connector” on page 205
• “Vertical mount contact connector” on page 208
• “Horizontal sliding contact connector” on page 211
• “Low Insertion Force (LIF) connector” on page 214
Zero Insertion Force (ZIF) connectors
Zero Insertion Force (ZIF) connectors are used on the boards and cards used in this printer. Before inserting or removing
a cable from these connectors, read this entire section. Great care must be taken to avoid damaging the connector or
cable when inserting or removing the cable.
Warning—Potential Damage: Do not insert the cable so that the contacts are facing the locking actuator. The
contacts always face away from the actuator.
Warning—Potential Damage: Do not insert the cable diagonally into the ZIF socket. This can cause damage to the
contacts on the cable.
Warning—Potential Damage: Avoid using a fingernail, or sharp object to open the locking mechanism. This could
damage the cable.
Warning—Potential Damage: Avoid pressing against the cable when opening the locking mechanism. This can also
damage the cable.
These are the types of ZIF connectors used in this printer:
• Horizontal top contact connector
• Horizontal bottom contact connector
• Vertical mount contact connector
• Horizontal sliding connector