 UMX-TPS-TX100 series – User's Manual 129


The recognized message is stored as a hex message in the below property till the next recognized message
or until the clear() method is called.
Command and Response
ç <loc>.RxHex
æ <loc>.RxHex=
<recognized_hex_data>
Example
ç 
æ 
Clearing the Last Recognized Stored Message
This method clears the stored recognized messages from Rx, RxHex and Hash properties.
Command and Response
ç <loc>:clear()
æ <loc>:clear
Example
ç 
æ 

The recognized data is stored in string in the below property temporaryActiveTimeout
property is elapsed, the property is cleared.
TIPS AND TRICKS: 
follow each other, the action will execute every occasion. (A Condition can be detected in Event Manager if
a change happens. In this case, the string is stored in the property and after the ActiveTimeout it will be
cleared. If the same string is saved into the (empty) property that will cause a change.)
Command and Response
ç <loc>.ActiveRx
æ pr<loc>.ActiveRx=<recognized_string>
Parameters
The <recognized_string> parameter is a max. 12 byte-long recognized data string.
Example
ç 
æ 
INFO: Please note that the property contains the string until the ActivePropertyTimeout is elapsed only.

Command and Response
ç <loc>.ActiveRxHex
æ <loc>.ActiveRxHex=
<recognized_hex>
Parameters
The <recognized_hex> parameter is the recognized data in hex format.
Example
ç 
æ 
INFO: Please note that the property contains the data until the ActivePropertyTimeout is elapsed only.
Set the Active Timeout
This property is responsible for clearing the ActiveRx, ActiveRxHex, ActiveHash properties after the elapsed
time. Default value is 50ms.
Command and Response
ç <loc>.ActivePropertyTimeout=<a_timeout>
æ <loc>.ActivePropertyTimeout=<a_timeout>
Parameters
The <a_timeout> parameter is the active timeout value (ms) between 0 and 255.
Example
ç 
æ 
Running an Immediate Event Action


Command and Response
ç <loc>.ActionTrigger=<event_nr>
æ <loc>.ActionTrigger=<event_nr>
Parameters
The <event_nr> means the number (location) of the linked Event Action without letter 'E'. (There is no need

Example
ç 
æ 

Table of Contents

Other manuals for Lightware UMX-TPS-TX140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware UMX-TPS-TX140 and is the answer not in the manual?

Lightware UMX-TPS-TX140 Specifications

General IconGeneral
BrandLightware
ModelUMX-TPS-TX140
CategoryTransmitter
LanguageEnglish

Related product manuals