8. Firmware Update UMX-TPS-TX100 series – User's Manual 154

Device Info
The most important information about the selected device is displayed; see the example for more details.
Command
LightwareDeviceUpdaterV2_CLI.cmd deviceInfo [options]
Options
Option Description Required?
-i or --ip 
one of them is
mandatory
-n or --hostName 
-v or Shows installed package version only optional
Example 1
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd deviceInfo --ip
192.168.1.14
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar deviceInfo --ip
192.168.1.14
Product name: UMX-TPS-TX140K
IP address: 192.168.1.14
Serial number: 00006363
MAC address: a8:d2:36:ff:63:63
Part number: 91540050
Device label: UMX-TPS-TX140K
Package version: v1.5.0b4
CPU FW version: v1.5.0b4
HW version: V20_DAX0
Operation mode: Application mode
Example 2
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd deviceInfo --ip
192.168.1.14 --packageVersion
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar deviceInfo --ip
192.168.1.14 --packageVersion
v1.5.0b4
Update

Command
LightwareDeviceUpdaterV2_CLI.cmd update [options]
Options
Option Description Required?
-p or --package  yes
-i or --ip 
one of them is
mandatory
-n or --hostName 
-b or --backupFolder


optional
-f or --factoryDefault Apply factory reset during device update. Default: false optional
-r or --reportProgress Report update progress in percentage form. Default: false optional


at this command; see the Unmute Audio Output section.
optional
ATTENTION! 
update command.In that case, there is no need to run the restore command after the update.
Example
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>LightwareDeviceUpdaterV2_CLI.cmd update --ip
192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --reportProgress
C:\Program Files (x86)\Lightware\Lightware Device Updater V2>lib\jre\bin\java.exe -jar lib\ldu2.jar update --ip
192.168.1.14 --package c:\Firmwares\umx-tps-tx100_v1.5.0b4.lfp2 --reportProgress
[2021-05-14 12:52:51.597] [ INFO] [ main] - Device IPs: [192.168.1.14]
[2021-05-14 12:52:55.786] [ INFO] [ main] - All the selected devices are accessible over the network.
[2021-05-14 12:52:56.032] [ INFO] [ main] - All the selected devices are compatible with the specified
package.
[2021-05-14 12:52:56.600] [ INFO] [ 192.168.1.14] - Package version: 1.5.0b4
[2021-05-14 12:52:56.780] [ INFO] [ 192.168.1.14] - Login functionality is currently not enabled.
[2021-05-14 12:52:56.816] [ INFO] [ 192.168.1.14] - Creating backup of device settings...
[2021-05-14 12:53:00.517] [ INFO] [ 192.168.1.14] - Backup HTTP enable properties
[2021-05-14 12:53:01.051] [ INFO] [ProgressReporter] - Progress: 2%
[2021-05-14 12:53:02.928] [ INFO] [ 192.168.1.14] - HTTP and HTTP post have got enabled on port 80
[2021-05-14 12:53:03.080] [ INFO] [ 192.168.1.14] - No miniweb file is found on the device.
[2021-05-14 12:53:05.566] [ INFO] [ 192.168.1.14] - HTTP and HTTP post properties have got restored on port 80
[2021-05-14 12:53:05.613] [ INFO] [ 192.168.1.14] - Switching device into bootload mode...
[2021-05-14 12:53:06.053] [ INFO] [ProgressReporter] - Progress: 5%
[...]
The lines containing "ProgressReporter" can be enabled optionally. If it is enabled, the current state is
displayed in every 5 seconds.

Table of Contents

Other manuals for Lightware UMX-TPS-TX140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lightware UMX-TPS-TX140 and is the answer not in the manual?

Lightware UMX-TPS-TX140 Specifications

General IconGeneral
BrandLightware
ModelUMX-TPS-TX140
CategoryTransmitter
LanguageEnglish

Related product manuals