Crane operation
11.5 Working range limiter
Operating Manual GMK6300L 3 112 xxx en 11 - 127
xx.xx.xxxx
11.5.6 Shutdown by working range limiter
If a limit value is reached, RCL shutdown will occur. All movements that
would go closer to the limit value will be disabled. Shutdown will remain
active even if you switch off the monitoring function.
The RCL also shows an error message. To enable the movements, you must
leave the shutdown range and acknowledge the error message;
à Table of
error codes
, p. 14 - 31.
If you override the RCL, the shutdown will be overridden and all movements
enabled.
Shutdown point reached for Disabled movements
Overall height
–Raise
– Extending
– Lowering the hoist
–Derricking the
lattice extension
Working radius
–Lower
– Extending
– Lifting the hoist
– Derricking the lattice extension
Slewing angle A – Slew to the left
Slewing angle B – Slew to the right
Objects
Depending on the position of the
object:
– Slewing to the left or right
–Lower
– Extending
– Lifting the hoist
– Derricking the lattice extension
G
Risk of accidents due to overriding shutdown procedures!
Only override RCL if it is absolutely necessary and you have a clear view of
the danger area. Bear in mind that, due to the boom bending for example,
the overall height is increased if you set down the load.