EasyManuals Logo
Home>Manitowoc>Construction Equipment>Grove GMK6300L-1

Manitowoc Grove GMK6300L-1 User Manual

Manitowoc Grove GMK6300L-1
1004 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #388 background imageLoading...
Page #388 background image
Malfunctions in driving mode
7.3 Towing the truck crane
7 - 10 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
7.3.3 External starting socket
The truck crane is equipped with a socket for external starting (1) on the
carrier and on the superstructure (
à p. 14 - 79).
If the batteries are discharged, the power supply (24 V) of an auxiliary vehi-
cle or the socket (1) on the superstructure can be used for charging.
• Start the engine of the power source (24 V).
• (A) – Connect the cable (1) to the power
supply.
• Insert the plug (2) into the socket (3).
• Start the engine for driving.
• (B) – Withdraw the plug (2).
• Close the socket (3).
• Remove the cable (1) from the power
supply.
Performing a jump
start
The socket (1) can also be used to supply power to another vehicle
(with a 24 V on-board network).
• Start the engine for driving.
• (A) – Insert the plug (2) into the socket (3) on
the carrier.
• Connect the cable (1) to the vehicle requiring
the power (24 V).
• Start the engine of the vehicle that requires
the power.
• (B) – Withdraw the plug (2).
• Close the socket (3).
• Remove the cable (1) from the vehicle.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals