Malfunctions during crane operation
14.7 Other emergency operations
Operating Manual GMK6300L 3 112 xxx en 14 - 79
xx.xx.xxxx
14.7.2 Battery charger
Prerequisites – The engine must not be running and must be secured against unauthor-
ised use,
– An external 230 V mains power supply must be available at the location,
– The location must be well ventilated and protected against moisture.
Connecting
• Insert the plug (1) into the socket (2).
• Place the battery charger (5) in a protected
place where you can see the indicator
lamp (3).
The battery charger can be suspended from
the ring eyes (4).
• Insert the plug (6) into the socket on the
mains supply 230 V at the location.
The battery charger switches on. The lamp (3)
on the battery charger indicates the status:
Disconnecting
• Withdraw the plug (3) from the socket.
• Withdraw the plug (1) from the socket (2).
• Close the socket (2).
• Return the battery charger to the storage
compartment in the driver's cab.
G
Risk of explosion when operating the battery charger!
The battery charger may not be operated:
– at service stations and tank farms,
– at places where flammable gases or vapours can be found or formed
(e.g. at places where fuel is stored and in chemical factories),
– at places where explosive dust can be found or formed (e.g. carbon dust,
wood dust and grain dust).
– Flashing: The battery is being charged
–On: Charging complete