Rigging work
12.2 Choice of a suitable positioning site
Operating Manual GMK6300L 3 112 xxx en 12 - 13
xx.xx.xxxx
12.2.3 Earthing the truck crane
The truck crane may become charged with static electricity. This may occur
especially when using outrigger pads made of plastic or when the outrigger
pads are packed with insulating material (e.g. wooden planks).
Use electrically conducting material for
earthing.
• Hammer a metal rod (3) (length approx.
2.0 m (6.6 ft)) at least 1.5 m (5 ft) into the
ground.
• For better conductivity, dampen the soil
around the metal rod (3).
• Clamp an insulated cable (2) to the metal
rod (3) (cross-section of at least 16 mm
2
(0.025 in
2
)).
• Connect the free end of the cable using
a clamp (1).
• Attach the clamp to the main boom or to the superstructure.
B
Risk of accidents due to electric shock!
Earth the truck crane before you start to work with it
– near strong transmitters (radio transmitters, radio stations, etc.),
– near high-frequency switchgear substations,
– if a thunderstorm is forecast.
B
Risk of accidents due to electric shock!
Ensure that the connections between the cable and the clamp are electri-
cally conductive.
Do not attach the clamp to parts that are bolted on, such as valves, cover
plates or similar parts.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals