SEAWATER COOLED MODELS SERVICE MANUAL NUMBER 23
Page 6A-12 90-861326--1 MARCH 1999
2. Remove seawater pump body, quad ring and wear plate from bearing housing.
75275
a
b
c
d
a-Seawater Pump Body
b-Wear Plate
c-Bearing Housing
d-Quad Ring (Not Shown In This View)
3. Remove the impeller from seawater pump body.
Seawater Pump Reassembly
1. Lubricate seawater pump impeller with a water and soap solution. Install impeller into
housing by rotating and pushing it into place. Push it down until flush with housing.
71118
71150
a
a-Impeller
2. Place wear plate over bearing housing shaft.
Downloaded from https://needmanual.com/!