Doc# 0296-0018 • REV R (July 2017) Page 7 of 61
Capabilies (connued)
Phase
During sensivity calculaon when the transducer selected is an acelerometer, the unit
displays the phase of the “transducer under test” relave to the internal reference acceler-
ometer.
Automac Mass Load Correcon
A special algorithm is used to automacally adjust measurements and calculaons to com-
pensate for the mass load of the transducer under test.
Help Screens
Help screens are provided during operaon to assist the operator.
Large Memory
Test parameters, test results and other test data can be stored in memory for future down
load via the printer. Informaon will be retained even though the TTS is turned o.
Printer
The TTS features a built-in thermal printer, which is used to hard copy data stored in memory.
Automac Date/ Time
A built-in real me clock displays date/me and automacally stamps hard copy print outs.
Baery Powered
Power is provided by two gel cell type baeries. The two baeries are charged via two built-
in charging systems that use a 110 VAC 50/60 Hz source. The user can use the TTS while the
baeries are being charged. 220 VAC is oponal.
ICP Accelerometers
Selectable current sources (.5 mA, 2 mA, 2.5 mA, 4 mA, 4.5 mA, 6 mA) are provided to power
ICP accelerometers.
Reference Accelerometer Output
A 50 mV/g, low impedance ( ~ 100 Ohms) reference accelerometer output signal is provided.
Automac Power Management
A power management and supervisory system is used to opmize power consumpon,
increasing the me between required charging. The instrument will automacally
turn o at the lowest acceptable voltage to ensure the baeries are not subjected to deep
discharge which can greatly reduce their operaonal life.
Automac Monitoring and Supervisory Limits
1. Warning - When test amplitude and/or frequency are out of acceptable ranges, the
operator is warned of the condion with ashing displays.
2. Shutdown - to prevent damage to the shaker, the TTS is automacally shut down when
maximum acceptable displacement limits are exceeded (approximately .125 inch P-P dis-
placement).
Principles of Operaon
The HI 803 Transducer Test Set is comprised of a Signal Generator, Power Amplier, Electro
dynamic Vibrator, Reference Accelerometer, Digital Voltmeter, Microcomputer and Digital
Indicator.