Technical Information
46
DG 408x Steam Ovens
3.16 When Touching a Keypad, Tone is Too Loud or Too Soft
Cause:
Keypad volume can be programmed. The keypad tone can also be turned on or off.
Remedy:
See Section 060-4.1.
3.17 System Lock Is Possible/Not Possible
Symptom:
The lock icon is not present in the display.
Cause:
To accept or not to accept the system lock can be programmed.
Remedy:
See Section 060-4.1.
3.18 Temperature in °C / °F
Cause:
The temperature format can be programmed.
Remedy:
See Section 060-4.1.
4 Service
4.1 Programming Mode
Initial requirements:
Shut off the appliance.
Accessing:
Note:
Access has to be completed with 10 seconds.
1. Touch and hold the Timer pad for DG 4082, or the Clear pad for DG 4080.
2. Touch and hold the On pad.
3. Release the Timer (Clear) and On pads at the same time.
4. Touch the Timer (Clear) pad five times and hold on the fifth time until the
programming mode appears.
Acknowledgement indicator:
The display shows the programming options.
LANGUAGE TEMPERATURE
CLOCK WATER HARDNESS
TEMPERATURES More
Options:
Touch the pad next to the desired option (refer to Table 060-2). Press Timer
(Clear) to go back one level.
Touch the pad next to the desired setting (refer to Table 060-2). Press Timer
(Clear) to go back one level.