4-15
4
4.2.8 Motor setting
Adjust the motor settings of the inverter. Click [Next] after inputting the motor information.
B
A
C
"Unit (monitor, frequency setting)" setting screen
(Example for IPM motor control)
DEFG
No. Name Function and description
A
Applied Motor
Select a type of motor. Selectable motor types are different according to the
control method selected in "Control Method" window (or Pr. 71 setting) .
B Motor information
Fill in the motor information. Required motor information to ll in is different
according to the control method setting selected in "Control Method" window.
C
Unit (monitor, frequency setting)
Change the Hz unit in the monitor display and the frequency setting to rpm when
necessary. This section is enabled when "IPM motor control" or "PM sensorless
vector control" has been selected in the "Control Method" window. (According to
the mounted communication option, the unit for monitor display and frequency
setting may always be Hz.)
D
Next> Proceeds to "Start Command and Frequency (Speed) Setting Method".
E
<Back Returns to "Control Method".
F Cancel Disables the settings and closes Easy Setup.
G Help Displays Help window.
* Some models have xed settings.