166
END
Operation Error
(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into
SD0.
Error
code
Error details
Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4200
The END instruction was executed before the execution of the NEXT
instruction and after the execution of the FOR instruction.
4211
The END instruction was executed before the execution of the RET
instruction and after the execution of the CALL, FCALL, ECALL, or
EFCALL instruction.
4221
The END instruction was executed before the execution of the IRET
instruction in an interrupt program.
4230
The END instruction was executed between the CHKCIR to CHKEND
instructions.
4231
The END instruction was executed between the IX to IXEND
instructions.