263
GS748T Smart Switch
5. Click Apply to send the ping. The switch sends the number of pings specified in the Count
field, and the results are displayed below the configurable data in the Result area.
• I
f successful, the output will be Send count=3, Receive count = n from (IPv6
Address).Average round trip time = n ms.
• I
f a reply to the ping is not received, the following displays: “Reply From IP/Host:
Destination Unreachable. Tx = x, Rx = 0 Min/Max/Avg RTT = 0/0/0 msec”.
Traceroute
Use the Traceroute utility to discover the paths that a packet takes to a remote destination.
To display this page, click Maintenance
Troubleshooting Traceroute.
To configure the Traceroute settings and send probe packets to discover the route to a host
on the network:
1. I
n the Hostname/IP Address field, specify the IP address or the hostname of the
station you want the switch to ping. The initial value is blank. This information is not
retained across a power cycle.
2. Opt
ionally, configure the following settings:
• Probes
Per Hop. Specify the number of times each hop should be probed. The valid
range is 1–10.
• MaxTT
L. Specify the maximum time-to-live for a packet in number of hops. The valid
range is 1–255.
• I
nitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range
is 0– 255.