5.4 Environmental specifications
Model Number FS-C4KU7DGES-F / FS-C4KU7DGES-M42 FS-C2KU7DGES-F / FS-C2KU7DGES-M42 /
FS-C2KU7DGES-C
Operational
Temperature /
Humidity
Minimum Environmental Temperature: 0 deg. C,
Environmental Humidity: 0 to 85 %RH (No condensation)
Maximum Environment Temperature: +40 deg. C or
Camera housing temperature (top plate) not exceeded +58 deg. C (*1),
Environmental Humidity: 0 to 85 %RH (No condensation)
Storage Temperature / Humidity Environmental Temperature: -20 to +80 deg. C,
Environmental Humidity: 0 to 85 %RH (No condensation)
Vibration 20 Hz to 200 Hz to 20 Hz (5 min. / cycle), acceleration 10 G, XYZ 3 directions, 30 min. each
Shock Acceleration 38 G, half amplitude 6 ms, XYZ 3 directions, 3 times each
Standard Compliancy EMS: EN61000-6-2, EMI: EN55011
RoHS RoHS Compliance
(*1) Please insure the camera is installed with the appropriate heat dissipation to keep the camera housing temperature
(top plate) is less than 58 deg. C when the camera using the environmental temperature is exceeded 40 deg. C.
When the internal temperature sensor on the camera shows less than 65 deg. C, the camera housing temperature
(top plate) will be less than 58 deg. C.
If the camera has a mounted lens and a tripod with an aluminum plate, this could decrease the camera housing
temperature for the heat dissipation.