Appendices
A - 70
NX-series EtherNet/IP Coupler Unit User’s Manual (W536)
This section gives the functions that were added or changed for each unit version of the EtherNet/IP
Coupler Unit.
The following table shows the unit version of the EtherNet/IP Coupler Unit, the unit version of the CPU
Unit, the unit version of the Industrial PC, and the version of the Support Software for changes in or
additions to the functions. You can use the added or changed functions with the versions/unit versions
given in the table or with later/higher versions.
Refer to version-related information given in the user’s manuals of the CPU Unit or Industrial PC for
corresponding versions when using CPU Unit versions, Industrial PC unit versions, and Support Soft-
ware versions that are the same or that are later or higher than the corresponding versions.
Depending on the type and model of the Unit, some Units do not have all of the versions given in the
corresponding versions. If a Unit does not have the specified version, support is provided by the oldest
available version after the specified version. Refer to the user’s manuals for the specific Units for the
relation between models and versions.
NX-EIC202
The following table shows the relationship when the NJ/NX-series CPU Unit is connected.
The following table shows the relationship when the NY-series Industrial PC is connected.
The following table shows the relationship when the CS1G/CS1H/CJ1H/CJ1M CPU Unit is con-
nected.
A-10-2 Functions That Were Added or Changed for Each Unit Version
Changes in and Additions to Functions
Function
Change
or addi-
tion
Ether-
Net/IP
Coupler
Unit
Corresponding unit version/version
NX
Unit
restric-
tions
Using an NX-series
CPU Unit
Using an NJ-series
CPU Unit
CPU Unit
Sysmac
Studio
CPU Unit
Sysmac
Studio
NX Unit control with CIP objects Addition Ver.1.2 Ver.1.14 Ver.1.19 Ver.1.14 Ver.1.19 None
Setting IO-Link devices from Support
Software other than the Sysmac Stu-
dio connected to peripheral USB port
on the EtherNet/IP Coupler Unit
Addition Not possi-
ble.
Not possi-
ble.
Not possi-
ble.
Not possi-
ble.
Yes
Communications Interface Unit control Addition Ver.1.14 Ver.1.19 Ver.1.14 Ver.1.19 Yes
BOOTP client Addition None
Function
Change
or addi-
tion
Ether-
Net/IP
Coupler
Unit
Corresponding unit version/version
Using an NY-series Industrial PC
NX Unit
restrictions
Industrial PC Sysmac Studio
NX Unit control with CIP objects Addition Ver.1.2 Ver.1.14 Ver.1.19 None
Setting IO-Link devices from Support
Software other than the Sysmac Stu-
dio connected to peripheral USB port
on the EtherNet/IP Coupler Unit
Addition Not possible. Not possible. Yes
Communications Interface Unit control Addition Ver.1.14 Ver.1.19 Yes
BOOTP client Addition None