1279
Model Conversion Instructions (Unit Ver. 3.0 or Later) Section 3-35
Example
#0082
&100
D00100
#0082
&200
m
m+1
GETID
A
m
m+1
Normal Operation
Using Function Blocks
DM Area allocated to
Motion Control Unit
Extended parameter
settings area
Indirect
specifica-
tion
The starting address of the extended parameter set-
tings area is specified by the FINS command variable
type (data area) code and word address. In this exam-
ple, #0082 specifies the DM Area and &100 specifies a
100-word offset from the beginning of the area.
DM Area allocated to
Motion Control Unit
Extended parameter
settings area
Variable A D00200
Data
Variable A's data area
address is retrieved by
GETID(286).