EPSILON CLOCK MODEL EC20S Spectracom
99 User’s Manual
17.2 TEMPERATURE STABILITY
- With an OCXO
Peak to peak, from 0 to 60°C : 1x10
-9
- With a Rubidium Oscillator
Peak to peak, from 0 to 50°C : 1x10
-10
17.3 ELECTROMAGNETIC COMPATIBILITY & ROHS COMPLIANCE
Complies with the requirements of the standards:
- EN 61000 – 6 – 3 : 2007 : Electromagnetic compatibility (EMC).Part
6-3: Generic standards - Emission standard for residential,
commercial and light-industrial environments.
- EN 61000 – 6 – 2 : 2005 : Electromagnetic compatibility (EMC) Part
6-2: Generic standards - Immunity for industrial environments.
- FCC Part 15 Edition 2008 Radio frequency devices Subpart B-
Unintentional Radiators Limits and methods of measurement of
radio disturbance Characteristic of information technology
equipment
- Information technology equipment. Radio disturbance characteristics. Limits and methods of
measurement.
The product complies with the requirements of the EMC Directive (2014/30/EU) and the Low Voltage Directive
(2014/35/EU).
SPECTRACOM hereby certifies that, to it’s knowledge, the Iisted supplies comply to the requirements of the
European Union’s Restriction on Use of Hazardous Substances in Electrical and Electronic Equipment (“ROHS”)
Directive, 2011/65/EU.
17.4 SAFETY
- EN 60950-1: 2006 + Am 11: 2009 + Am 1: 2010 + Am 12: 2011 + Am2: 2013 - Safety of Information
Technology Equipment.