5 – Managing Ports
Resetting a Port
5-18 59264-02 A
S
Auto Performance Tuning and AL Fairness
The Auto Perf Tuning and AL Fairness settings are configured using the
Advanced Port Properties dialog (Figure 5-5). The Auto Perf Tuning option
enables the switch to dynamically control the MFS_Enable, VI_Enable and
LCF_Enable features based on the operational state of the port. The AL Fairness
option controls how frequently the switch can arbitrate for access. Applies only
affects ports running in loop (FL) mode. To open the Advanced Port Properties
dialog, select one or more ports, open the Port menu, and select Advanced Port
Properties.
Figure 5-5 Advanced Port Properties Dialog
Resetting a Port
The Reset Port option reinitializes the port using the saved configuration. To reset
a port, do the following:
1. In the faceplate display, select the port(s) to be reset.
2. Open the Port menu and select Reset Port.
3. Click the Yes button to reset the selected port(s).
NOTE:
Use the Select to Propagate Changes to Entire Column options to
propagate the same change to all selected ports, select the options before
making a change to a port.