10
10-26
MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
32180 Group User’s Manual (Rev.1.0)
10.2.5 Output Flip-flop Control Unit
The Output Flip-flop Control Unit controls the flip-flops (F/F) provided for each timer. Following flip-flop control
registers are included:
• F/F6–15 Source Select Register (FF615S)
• F/F16–19 Source Select Register (FF1619S)
• F/F0–15 Protect Register (FF015P)
• F/F16–20 Protect Register (FF1620P)
• F/F21–28 Protect Register (FF2128P)
• F/F29–36 Protect Register (FF2936P)
• F/F37–44 Protect Register (FF3744P)
• F/F0–15 Data Register (FF015D)
• F/F16–20 Data Register (FF1620D)
• F/F21–28 Data Register (FF2128D)
• F/F29–36 Data Register (FF2936D)
• F/F37–44 Data Register (FF3744D)
The timing at which signals are generated to the output flip-flop by each timer are shown in Table 10.2.5. (Note
that this timing is different from one at which signals are output from the timer to the output event bus.)