TPS-1 Users Manual: Hardware Appendix. A Setting of operating modes
R19UH0081ED0107 Rev. 1.07 page 69 of 86
Jul 30, 2018
IO Local Interface
For the development of small IO-Devices the TPS-1 offers the IO Parallel and IO Serial Interface. This interface can be used without an external Host
CPU.
.
IO Local parallel Interface
There are some restrictions when using the IO Local Parallel interface.
You can have only one Application Identifier (API).
It is only one module (slot) possible.
It is only one submodule (subslot) possible.
The input, output and diagnostic bits must be in a connected order.
You must always choose groups in byte range (8, 16, 24, 32, etc.).
Configuration of the IO Local Parallel Interface
The TPS Configurator supports the configuration of the IO Local Parallel Interface.
You can set all necessary parameters for the IO Local Parallel Interface (e.g. API, SlotNumber, ModuleIdentNumber, etc.). On the next program tap
you can configure the diagnostic channels.
Figure A-9: IO Local Parallel Interface Mask