Details
D454 114 SM
2.4 TRAY FULL
A pair sensors are used to detect the tray full condition. At the start of every job:
Tray full sensor (Emitter) [A] emits a signal to tray full sensor (Receptor) [B].
As long as the signal remains unbroken the multi-folder will continue to operate and
feed folded paper to the top of the unit [C].
When the top of the stack grows high enough to interrupt the signal between the tray full
sensors [D], this will signal the machine to shut down the line temporarily.
After the operator removes the stack from the top tray, folding and paper exit will
resume.