Service Program Mode Tables
D062/D063/D065/D066 4-12 SM Appendix
-001
Power On Middle Thick
0 or 1
-002
Power On Thick
0 or 1
SP2xxx Drum
2001* Charge Roller Bias Adjustment
001 Applied Voltage for Image Processing
Adjusts the voltage applied to the grid plate during copying when auto process
control is off.
[600 to 1500/900/10 V]
After replacing the charge corona wire or the drum, reset to the factory default
setting.
002 ID Sensor Pattern: Adjustment of Applied Voltage
Adjusts the voltage applied to the grid plate when the ID sensor pattern is
created.
[600 to 1500/800/10 V]
003 Setting for Total Bias Current
Adjusts the total current applied to the charge corona wire. DFU
[900 to 1500/1300/10
A]
004 Setting for Total Bias Current of Grid
Adjusts the voltage applied to the grid plate during copying when auto process
control is on.
[600 to 1500/900/10 V]
This voltage changes every time auto process control starts up (every time the
machine is switched on).
005 Total Bias Grid Voltage: OHP Total
Adjusts the voltage applied to the grid plate when OHP mode is selected.