Resets
SM 5-5 D062/D063/D065/D066
System
Maintenance
5.2 RESETS
5.2.1 MEMORY ALL CLEAR: SP5801
Before shipping, the SP mode data settings are printed in an SMC Report and attached to
the exposure glass of the machine for your reference. Store this report in a safe place (next
to the toner collection bottle, for example). It is a list of all the SP initial settings. Refer to
this list if you need to initialize one or more SPs. The initial SP settings are also written in
the SP mode tables at the end of this section.
As a rule, you should always print an SMC Report before initializing or adjusting the SP
settings. The SMC Report provides a concise list of all the SP commands and their current
settings. The report can be used for reference if the service manual is not available.
Executing Memory All Clear resets all the settings stored in the NVRAM to their default
settings except the following:
SP5811-001 Machine serial number
SP5907 Plug & Play Brand Name and Production Name Setting
1. Execute SP5990 to print out all SMC Data Lists.
2. Open SP mode 5801.
3. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to initialize
all modules.
Memory Clear (See IMPORTANT NOTE in Section 5.4.2.)
5801
Resets NVRAM data to the default settings. Before executing any of these SP
codes, print an SMC Report.
001 All Clear Initializes items 2 to 15 below.
002 Engine Clear
Initializes all registration settings for the engine and
copy process settings.
003 SCS
Initializes default system settings, SCS (System Control
Service) settings, operation display coordinates, and
ROM update information.
004 IMH Memory Clear
Initializes the image file system. (IMH: Image Memory
Handler)
⇒
Rev. 07/15/2009