Table 5-4: QSHT 5700 Inverter Ground Screw Configurations
Ground Configuration
*
* The QSHT 5700 inverter must be spaced by aligning the zero-stack tab and cutout. For hole patterns, refer to
the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002
.
Ground Screw
Configuration
Benefits of Configuration
Grounded (wye) Installed
UL and EMC compliance.
Reduced electrical noise.
Most stable operation.
Reduced voltage stress on components
and motor bearings.
• AC-fed ungrounded
• Corner grounded
• Impedance grounded
Not installed (default
setting)
Helps avoid severe equipment damage
when ground fault occurs.
Reduced leakage current.
DC-bus from active converter