Transport System Limits
QuickStick HT User Manual 325
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Transport System Limits
Table A-4: MagneMotion Transport System Limits
Path Node Controller System (HLC)
Motors
20/RS-422
30/Ethernet
–
†
† When using RS-422 communications with the motors, limited by the number of RS-422 connections on the
node controller (NC LITE up to 4 connections, NC-12 up to 12 connections, NC-S up to 8 connections).
When using Ethernet communications with the motors, limited by the node controller configuration and pro-
cessor loading (NC LITE up to 5 nodes, NC-12 up to 16 nodes, NC-E up to 36 nodes, NC-S up to 16 nodes),
see the Node Controller Hardware User Manual, MMI-UM013.
3,840
Node Controllers ––96
Nodes 2–
†
256
Paths ––
†
128
Stations – – 2048
Vehicles
50/RS-422
*
300/Ethernet
* When using RS-422 communications with the motors, 50 vehicles maximum per path when all vehicles on
the path are commanded forward (downstream).
45 vehicles maximum per path when all vehicles on the path are commanded backwards.
384 5,120
‡
‡ 6,000 vehicles maximum when using HLC Control Groups.
Table A-5: MagneMotion Transport System Motion Limits
*
* The limits that are shown are at the typical payloads (contact ICT Customer Support for payload guidance).
Use of a smaller payload may permit higher limits. Use of a larger payload may lower the limits.
Acceleration Velocity Thrust
MagneMover
®
LITE
†
† The limits that are shown are for standard MagneMover LITE glide pucks. Using other pucks, or custom ve-
hicles, may permit different limits.
2.0 m/s
2
[0.2 g] 2.0 m/s [4.5 mph] 10.0 N/cycle
‡
‡ Thrust at 25% duty cycle, nominal Vehicle Gap is 1 mm for G3 and 1.5 mm for G4.2.
QuickStick
®
100 9.8 m/s
2
[1.0 g] 2.5 m/s [5.6 mph] 16.3 N/cycle
§
§ Thrust at 4.0 A stator current with a nominal Vehicle Gap of 3 mm with a standard magnet array.
QuickStick
®
HT 60.0 m/s
2
[6.1 g] 3.5 m/s [7.8 mph] 182.0 N/cycle
**
** Thrust at 10.9 A stator current with a nominal Vehicle Gap of 12 mm with a high flux magnet array.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MMI-HT-C2198-D032 and is the answer not in the manual?

Rockwell Automation MMI-HT-C2198-D032 Specifications

General IconGeneral
BrandRockwell Automation
ModelMMI-HT-C2198-D032
CategoryAccessories
LanguageEnglish

Related product manuals