Design Guidelines
Transport System Design
80 MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Ethernet Motor Connection Examples
The QuickStick HT 5700 Inverters, which use Ethernet for inverter to inverter communication
and for inverter to node controller communication can use different network topologies
depending on the application. When using Ethernet communications, the inverters for all
motors in a specific path must be on the same network as the node controller (see Figure 3-15
through Figure 3-26). Additionally, the inverters for all motors and the location of the motors
in the transport system must be defined in the MICS file (see Ethernet Motor MICS File on
page 89).
Order of Modules
When using linear (chained) Ethernet communication with the QSHT motors, the order of the
modules on the chain is important. This is because if a module on the chain experiences an
anomaly, all modules after it on the chain could lose their communication to the network
switch and node controller.
To make sure that an anomaly in a QSHT 5700 inverter does not interrupt power to all invert-
ers in the chain, the 2198-Pxxx DC-bus power supplies for the inverters in the chain must be
the first modules in the chain as shown in Figure 3-13. There is a maximum of 16 inverters per
power supply, power dependent. The power supplies can also be connected directly to the
Ethernet switch and not part of the Ethernet chain as shown in Figure 3-14.
Figure 3-13: Ethernet Wiring – Power Supply In-line with Inverters
Figure 3-14: Ethernet Wiring – Power Supply Separate from Inverters
P1M1
x.y.1.1
P1M2
x.y.1.2
P1M3
x.y.1.3
P1M4
x.y.1.4
Simpl e QSHT Motor
Host
Controller
Enet
Switch
QSHT 5700
Inverter
Ethernet
QSHT Motor
QSHT 5700
Inverter
QSHT Motor
QSHT 5700
Inverter
QSHT 5700
Inverter
TermQSHT Motor
x.y.0.10
HLC &
Node
Controller
Straight Transport System (Recommended):
One Ethernet Connection to Switch
Power Supply - Inline
One Chain
One Path
Power
Supply
x.y.0.11
Shared-bus Connection Systems
(DC-bus and 24V DC)
Ethernet
Power
Drive
Sense
Downstream
Simpl e QSHT Motor
Host
Controller
Enet
Switch
QSHT 5700
Inverter
Ethernet
QSHT Motor
QSHT 5700
Inverter
QSHT Motor
QSHT 5700
Inverter
QSHT 5700
Inverter
TermQSHT Motor
x.y.0.10
HLC &
Node
Controller
Straight Transport System (Recommended):
One Ethernet Connection to Switch
Power Supply - Star
One Chain
One Path
Power
Supply
x.y.0.11
P1M1
x.y.1.1
P1M2
x.y.1.2
P1M3
x.y.1.3
P1M4
x.y.1.4
Shared-bus Connection Systems
(DC-bus and 24V DC)
Ethernet
Power
Drive
Sense
Downstream

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MMI-HT-C2198-D032 and is the answer not in the manual?

Rockwell Automation MMI-HT-C2198-D032 Specifications

General IconGeneral
BrandRockwell Automation
ModelMMI-HT-C2198-D032
CategoryAccessories
LanguageEnglish

Related product manuals