Chapter 2 Power Component Definition and Maintenance
Snubber Capacitance (SCR Device)
Turn the multimeter from the resistance to capacitance measurement mode.
Proceed to verify the snubber capacitor by measuring from the test point and
the white wire at the 2-pole device snubber plug (labeled snubber).
Figure 77 - Snubber Capacitance Test
To test the snubber capacitance, disconnect the plug of the self-powered gate
driver board labeled SHARING and SNUBBER. The resistance between the
white wire of the plug and the Test Point to its left is the snubber capacitance.
See Table 7 on page 78
to determine the appropriate snubber capacitance value
for the current rating of the SCR used. Read the actual snubber capacitor value
shown in the table.
If the capacitor is out of tolerance, see page 76
for the snubber capacitor
replacement procedure.
HeatsinkHeatsink
To Gate Driver Board
Heatsink
Heatsink
Snubber
Resistor
Snubber
Capacitor
Sharing Resistor
Test Point
Resistance value between test point and white
wire at 2-hole plug is snubber capacitance

Table of Contents

Other manuals for Rockwell Automation PowerFlex 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex 7000 and is the answer not in the manual?

Rockwell Automation PowerFlex 7000 Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex 7000
CategoryDC Drives
LanguageEnglish

Related product manuals