43410 WORKAREA_MINUS_ENABLE - A3
- Working area limitation active in the negative direction BOOLEAN Immediately
CTEQ
- - FALSE 0 - 7/7 U
Description: 1: The working area limitation of the axis concerned is active in the negative
direction.
0: The working area limitation of the axis concerned is switched off in the negative
direction.
The setting data is parameterized via the operator panel in the operating area
"Parameters" by activating/deactivating the working area limitation.
SD irrelevant for ......
G code: WALIMOF
43420 WORKAREA_LIMIT_PLUS - A3
mm, degrees Working area limitation plus DOUBLE Immediately
-
- - 1.0e+8 - - 7/7 U
Description: The working area defined in the basic coordinate system in the positive direction of
the axis concerned can be limited with axial working area limitation.
The setting data can be changed on the operator panel in the operating area
"Parameters".
The positive working area limitation can be changed in the program with G26.
SD irrelevant for ......
G code: WALIMOF
Related to ....
SD43400 $SA_WORKAREA_PLUS_ENABLE
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
43430 WORKAREA_LIMIT_MINUS - A3
mm, degrees Working area limitation minus DOUBLE Immediately
-
- - -1.0e+8 - - 7/7 U
Description: The working area defined in the basic coordinate system in the negative direction of
the axis concerned can be limited with axial working area limitation.
The setting data can be changed on the operator panel in the operating area
"Parameters".
The negative working area limitation can be changed in the program with G25.
SD irrelevant for ......
G code: WALIMOF
Related to ....
SD43410 $SA_WORKAREA_MINUS_ENABLE
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
43700 OSCILL_REVERSE_POS1 - P5
mm, degrees Oscillation reversal point 1 DOUBLE Immediately
-
808d-me42 - 0.0 - - 7/7 U
NC setting data
Parameter Manual
346 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1