808d-me62 - 2 0 3 0/0
808d-te42 - 2 0 3 0/0
808d-te62 - 2 0 3 0/0
808d-mte40 - 3 0 3 7/2
808d-mte60 - 3 0 3 7/2
Description: Path on which the user program set with MD11620 $MN_PROG_EVENT_NAME is called in
response to an event-driven program call configured with MD20108 $MC_PROG_EVENT_MASK:
0: /_N_CMA_DIR
1: /_N_CUS_DIR
2: /_N_CST_DIR
3: Search path in the sequence /_N_CUS_DIR, /_N_CMA_DIR, and /_N_CST_DIR
11717 D_NO_FCT_CYCLE_NAME EXP, N12, N07 K1
- Subroutine name for D function replacement STRING PowerOn
-
- - - - - 2/2
Description: Cycle name for replacement routine of the D function.
If a D function is programmed in a part program block, then, depending on machine data
MD10717 $MN_T_NO_FCT_CYCLE_NAME, MD10719 $MN_T_NO_FCT_CYCLE_MODE and MD10718
$MN_M_NO_FCT_CYCLE_PAR, the MD subprogram defined in MD11717 $MN_D_NO_FCT_CYCLE_NAME
is called.
The programmed D number can be polled in the cycle via system variable $C_D /
$C_D_PROG.
MD11717 $MN_D_NO_FCT_CYCLE_NAME is only active in Siemens mode (G290).
No more than one M/T/D function replacement can be active per part program line.
A modal subprogram call must not be programmed in the block with the D function
replacement. Furthermore, neither subprogram return nor part program end are allowed.
In the event of a conflict alarm 14016 is output.
12000 OVR_AX_IS_GRAY_CODE EXP, N10 V1, Z1
- Axis feedrate override switch Gray-coded BOOLEAN PowerOn
-
- - TRUE 0 - 1/1
Description: This machine data is used to adapt the axis feed override switch to the interface
coding of the PLC interface.
1: The 5 low-order bits of the PLC interface signal DB380x DBX0 (Feed override A-H)
are interpreted as a Gray code. The value which is read corresponds to a switch
setting. It is used as an index for selecting the correct override factor from the
table of MD12010 $MN_OVR_FACTOR_AX_SPEED [n].
0: The feed override byte of the PLC interface is interpreted as a binary
representation of the override value in percent (limit 200 percent).
Related to:
NC/PLC interface signal DB380x DBX0 (Feed override A-H), (axis-specific)
MD12010 $MN_OVR_FACTOR_AX_SPEED [n]
(Evaluation of the axis feed override switch)
12010 OVR_FACTOR_AX_SPEED EXP, N10 V1, Z1
- Evaluation of axis feedrate override switch DOUBLE PowerOn
-
- 31 0.00, 0.01, 0.02, 0.04,
0.06, 0.08, 0.10, 0.20...
0.00 2.00 1/1
Machine data
3.2 General machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 75

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals