808d-te42 - 0x0 0 0x1 0/0
808d-te62 - 0x0 0 0x1 0/0
808d-mte40 - 0x0 0 0x1 7/2
808d-mte60 - 0x0 0 0x1 7/2
Description: Settings for VDI signals:
Bit 0 == 0:
The VDI signals motion command + / motion command - are already issued if there is a
travel request (default).
Bit 0 == 1:
The VDI signals motion command + / motion command - are issued only if the axis
actually moves.
17950 IS_AUTOMATIC_MEM_RECONFIG EXP, N02 -
- System: automatic memory reconfiguration BOOLEAN PowerOn
-
- - TRUE - - ReadOnly
Description: Value = 0 : If machine data that redefines the buffered memory is modified, then
generally the alarm
4400 is output which indicates that the user data will be deleted
the next the software is started.
Value = 1 : If machine data that redefines the buffered memory is modified, then
generally the alarm
4400 is not output. This means the data is retained the next time
the software is started.
The preassigned value is selected model-specifically and generally it must not be
changed.
17951 AUTOMATIC_MEM_RECONFIG_FILE EXP -
- Path and file name for internal data backup STRING PowerOn
-
- - /siemens/sinumerik/
sys_cache/nck/
content.reconfig
- - ReadOnly
Description: File name with file path where the data backup file is stored if the persistent memory
is reconfigured.
18030 HW_SERIAL_NUMBER N05 -
- Hardware series number STRING PowerOn
-
- 1 - - - 2/-
Description: During power on of the control, a unique hardware serial number is stored in this MD:
● For Powerline series modules this is the serial number of the NCU module
● For Solutionline series modules this is the serial number of the CF card, or the
unique number of the MCI module in the case of PC-based systems
This data cannot be written.
18040 VERSION_INFO N05 -
- Version STRING PowerOn
-
- 5 - - - 2/-
Description: Version identifiers of the system software
Machine data
3.2 General machine data
Parameter Manual