18050 INFO_FREE_MEM_DYNAMIC N01, N02, N05 S7
- Display data of the free volatile memory DWORD PowerOn
-
- - 1310720 0 268435456 1/-
Description: The data is used for
a) the manufacturer's presetting of the memory size [ bytes ] available to the user
for each channel after cold restart.
b) displaying the available volatile memory [ bytes ]
The data cannot be written.
The contents of the data state how much volatile memory is available per channel for
increasing the volatile user data storage area via MD.
It is advisable to check whether the available memory is sufficient before increasing,
for example, the number of LUDs, number of functional parameters, or the size of the
IPO buffer.
If necessary, proceed step by step:
● increase by 1, note (old) value
● NCK startup (= 'warm start' or NCK reset), read off new value
● memory requirement = new value - old value
18060 INFO_FREE_MEM_STATIC N01, N02, N05 S7
- Display data of the free nonvolatile memory DWORD PowerOn
-
- - 409600 0 48234496 1/-
Description: The preassigned value specifies how many bytes, as a minimum, are free for the user
when the NCK runs up with a 'cold restart'.
The contents of the data state how much nonvolatile memory is available during startup
for configuration of the active and passive file system and other functions.
e.g. MD18082 $MN_MM_NUM_TOOL
e.g. MD18150 $MN_MM_GUD_VALUES_MEM
e.g. MD18352 $MN_MM_U_FILE_MEM_SIZE
e.g. MD38000 $MA_MM_ENC_COMP_MAX_POINTS)
On the first NCK power-up or cold restart of the control (=deletion of user data)
MD18230 $MN_MM_USER_MEM_BUFFERED is set by the NCK software so that at least the
default value results for MD18060 $MN_INFO_FREE_MEM_STATIC.
Machine data for configuration of functions that require nonvolatile memory (tools,
GUDs, compensations, ...) can be increased until this memory has all been allocated.
18082 MM_NUM_TOOL N02, N09 FBWsl, S7
- Number of tools the NCK can manage (SRAM) DWORD PowerOn
-
808d-me42 - 64 0 64 ReadOnly
808d-me62 - 64 0 64 ReadOnly
808d-te42 - 64 0 64 ReadOnly
808d-te62 - 64 0 64 ReadOnly
808d-mte40 - - 0 128 ReadOnly
808d-mte60 - - 0 128 ReadOnly
Description: The NC cannot manage more tools than the number entered in the MD. A tool has at least
one cutting edge.
Buffered user memory is used.
Machine data
3.2 General machine data
Parameter Manual