143MS 261, MS 261 C
13.8 Wiring Harness
If there is a fault in the wiring
harness, replace the wiring
harness.
– Remove the shroud,
12.4.1
: Pull the generator wire (1) and
connector with insulating tube (2)
out of the guides (arrows).
5902RA547 TG
1
2
: Push back the insulating tube (1)
in the direction of the generator
wire and separate the pin and
socket connector.
: Take out the screw (1).
– Lower the tank housing (2).
: Take out the screws (1).
: Lift the handlebar (2) a little and
ease it to the side.
5902RA548 TG
1
5902RA549 TG
1
2
5902RA550 TG
1
1
2
: Pull out the cover (1).
: Pull the pin and connector with
insulating tube (1) out of the
guide (arrow).
: Push back the insulating tube (1)
in the direction of the wiring
harness and separate the pin and
socket connector.
5902RA277 TG
1
5902RA551 TG
1
5902RA552 TG
1