Page #148 background imageLoading...
Page #148 background image
145
TROUBLESHOOTING TROUBLESHOOTING
Bleeding the Air from the Fuel
System
1. Supply fuel.
2. Turn the starter key to the ON position and
hold it there for about 20 seconds.
The automatic air bleeder bleeds the air
from the fuel system.
Supplement: Air in the fuel system can
make it difficult to start the engine and cause
engine problems. Also bleed the air when
the fuel tank is emptied or air in the fuel
system.
Disconnecting the jumper cables
Once the engine starts, disconnect the
jumper cables following the connection
procedure in reverse order.
1. Disconnect the clip of jumper cable (B)
from the problem vehicle’s engine block.
2. Disconnect the other clip of jumper cable
(B) from the rescue vehicle’s “–” terminal.
3. Disconnect the clip of jumper cable (R)
from the rescue vehicle’s “+” terminal.
4. Disconnect the other clip of jumper cable
(R) from the problem vehicle’s “+” terminal.
Recharging
Have a Takeuchi sales or service outlet
recharge batteries that have gone dead.
If the Battery Goes Dead After the Fuel Runs Out
Rescue vehicle battery Problem vehicle battery
From engine block
OFF
ON
START
L3D001
E4J006
4
1
3
2
R
B