R-GPIB Commands Variable: Value TDSUSB2 Command Arguments and Queries- Results
Variable: Value TDSUSB2 Command Arguments and Queries- Results
Variable Name Valid value Function
Query Form
resultFor
{eye, sigrt, jk, kj, con, eop,
eopbit, cross, rer, fer, mon,
in, pphost1, pphost2,
pphost3, ppdevice1,
ppdevice2,resume,sus-
pend,
rfr, rfs, chirphost1,
chirphost2,
chirpdevice1}
Sets the result variables
with appropriate result
values for that particular
test
After being set to a
measurement value, the
query returns "Busy" until
the results are refreshed.
Returns the selected
measurement for result
querying
reset
{Result} Clears the active
measurements results
Statistical results- Basic statistics applicable for all SQC measurements
measUnits
Units string for the
measurement (for example
“s” - seconds is the unit for
Period)
max
Maximum value of the
measurement
mean
Mean value of the result
min
Minimum value of the
measurement
pkpk
Peak-to-peak value of the
measurement
rms
RMS value of the result
population
Population (number of)
measurements used to
calculate the current
statistics
stdDev
Standard deviation
measurement set
status
{Pass, Fail, C onditional
Pass}
Returns Pass/Fail result
for the selected SQC
measurement
Pass/Fail Status
eyeStatus {Pass, Fail, Conditional
Pass}
Returns the eye diagram
measurement
sqcOverallStatus {Pass, Fail, Conditional
Pass}
Returns the overall SQC
measurement result
Inrush
inCharge
Returns the inrush charge
value
TDSUSB2 Universal Serial Bus Measurements Package 139